Demodulation frequency | 8,20 Hz to 20 kHz |
ResidualFM(to CCITT) | <24Hz |
FM broadbanddemodulator | |
Frequency range | 40 to 2000MHz |
Modulation fraquencyrange | up to 130 kHz |
Deviation(presettable range limits) | 130/260/520kHz |
ResdualFM(measured at demodulator output,rms weighting,130kHz bandwidth,range limit 130kHz |
RF<1000MHz | <200Hz |
RF>1000MHz | <200Hz |
Accuracy (of reaeing with peak weighting) | |
AF<20kHz | 3%+residual FM+resolution |
AF<100kHz | 5%+residual FM+resolution |
AF<130kHz | 7%+residual FM+resolution |
Phase deviation meter | +PK,-PK,±PK/2,PKHold,NAXPD or RMS |
Measurement range | 0.0001to 25 rad |
Demodulation frequency range | 300Hz to 10kHz |
Peak weighting or automatic switchoverat 0.1 rad |
AM measurement | |
Operating modes | +PK,-PK,±PK/2,PK Hold,NAXPDor RMS |
Measurement range | 0.01to 99% |
Frequency range | 1.5to 2000MHz |
Pead weighting,rms weighting or automaticswitchover at 100 Hz deviation |
Trarsmitter andreceiver measurements |
Weightion filter | toCCITT filter specification,switchable 300Hz highpass filter |
Distortionmeasurement | |
Measurement frequency | 1kHz±1% |
Measurement range | 0.1 to 50% |
Resolution | 0.1% |
Inherentdistortion | ≤0.3% |
Accuracy | 5%of rdg +ingerent distortion |
SINAD measurement | |
Measurement frequency | 1kHz±1% |
Emasurement range | 1 to 46 dB |
Resolution | 0.1dB |
Accuracy | 0.5dB |
Modulation generator | |
Operating modes | singe-tone modulation,two-tonemodulation(option CMT-B7) |
Frequency range | 20Hzto 25kHz,usable up to 30kHz |
Resolution;f<1/3/6/10/20kHz | 0.1/0.2/1/2.5/10Hz |
f>20kHz | 20Hz |
Frequencyaccuracy | 0.5*resolution |
Fixedfrequencies | 8,programmable |
Outputvoltage | 10μV to 5V |
Accuracy(Vo>1mV) | 3% |
Selective-callencoder/decoder | |
Standard tonesequences | ZVEII,2/CCIR/EIA/EEA/EURO/VDEW/CCITT, NATELplus userdefined sequences |
Digits | 0to 9, to F |
Call length | 1to 25 tones |
Automatic repeat | canbe switched on/off |
Encoder | |
Frequency offset | adjustableup to ±10% |
Tone/interval duration | tostandard or programmable |
Decoder | tostandard or programmable tolerance evaluation to standard or progammable without-of-tolerance indication |
Oscilloscope | |
Displayed signals | externalsignal(Zout approx.1 MΩ,AC/DC coupling)AF,demod,signalAM,FM,фM),beat(AC corpling) |
Screensize | approx.6 cm * 4cm |
Verticaldeflection | |
External | 5mV/divto 10V/div |
AF voltmeter | 1mV/divto 20V/div |
Demod. AM | 0.1%/divto 40kHz/div |
FM | 5Hz/divto 40 kHz/div |
фM | 0.01to 10 rad/div |
Horizontal deflection | 0.01to 20 ms/div |
Bandwidth | DC/5Hz to 100kHz |
RF Millivoltmeter | optionCM-BB |
Frequency range | 10kHzto 1000 MHz |
Measurement range | 1mVto 10V,10mV to 100V(measurement range and frequency response depending on measuringhead) |
Readout | inmV,V,W,dBm or dBμV |
Resolution(V>100mV) | 1%,0.1dBm |
Accuracy(+20 to +25℃) | 5%+frequencyresponse error |
Aduacent-Channel PowerMeter | option CMT-B6 |
Frequencyrange | 4 to 1000MHz |
Channelspacing | 10/12.5/20/25kHz |
Dynamicmeasurement range | tyg.63dB |
Generaldata | |
IEC/IEEE-BusControl Interface | option CM-B4(IEC625/IEEE488) |
Control interface | 8relays(max.28V.0.25A,3VA)monual control,programmable |
AutorunControl/Printer Interface | option CM-B5 |
Storage capacity(battery-backed) | approx.100simple or 20 complex test programs |
DUTcontrol | 3 relays (max.28V,0.25A,3VA)manual control,programmable,Centronicsparallel interface |
Power supply | 100/120/220/240V±10% 47 to 420Hz,100VA |
Battery,CMT | 11to 30V(80W) |
Dimensions(W*H*D);weight | 420mm*220mm*340mm;19kg |