彩票天下

  • <tr id='5h33up'><strong id='5h33up'></strong><small id='5h33up'></small><button id='5h33up'></button><li id='5h33up'><noscript id='5h33up'><big id='5h33up'></big><dt id='5h33up'></dt></noscript></li></tr><ol id='5h33up'><option id='5h33up'><table id='5h33up'><blockquote id='5h33up'><tbody id='5h33up'></tbody></blockquote></table></option></ol><u id='5h33up'></u><kbd id='5h33up'><kbd id='5h33up'></kbd></kbd>

    <code id='5h33up'><strong id='5h33up'></strong></code>

    <fieldset id='5h33up'></fieldset>
          <span id='5h33up'></span>

              <ins id='5h33up'></ins>
              <acronym id='5h33up'><em id='5h33up'></em><td id='5h33up'><div id='5h33up'></div></td></acronym><address id='5h33up'><big id='5h33up'><big id='5h33up'></big><legend id='5h33up'></legend></big></address>

              <i id='5h33up'><div id='5h33up'><ins id='5h33up'></ins></div></i>
              <i id='5h33up'></i>
            1. <dl id='5h33up'></dl>
              1. <blockquote id='5h33up'><q id='5h33up'><noscript id='5h33up'></noscript><dt id='5h33up'></dt></q></blockquote><noframes id='5h33up'><i id='5h33up'></i>
                教育ω装备采购网
                第六届图书馆论■坛580*60

                人补体片断5a(C5a)ELISA试剂盒说明书

                教育装备采购网 2014-04-29 17:28 围观149次
                Human C5a ELISA Kit For the quantitative in vitro determination of Human Complement fragment 5a concentrations in serum - plasma - celiac fluid - tissue homogenate - body fluid FOR LABORATORY RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. This package insert must be read in its entirety before using this product.ELISAENZYME LINKED IMMUNOSORBENT ASSAYINTENDED USE AND TEST PRINCIPLEThis C5a ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of C5a in the sample, this C5a ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus C5a concentration. The concentration of C5a in the samples is then determined by comparing the O.D. of the samples to the standard curve.SAMPLE COLLECTION AND STORAGESSerum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximately 2000×g. Remove serum and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cyclesPlasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.MATERIALS REQUIRED BUT NOT SUPPLIED1. 37 ℃ incubator2. Standard microplate reader capable of measuring absorbance at 450 nm3. Precision pipettes, disposable pipette tips and Absorbent paper4. Distilled or deionized waterREAGENTS PROVIDED All reagents provided are stored at 2-8°C. Refer to the expiration date on the label. Name 96 determinations 48 determinationsMicroelisa stripplate 12*8strips 12*4stripsStandard(6 vial) 0.5ml/vial 0.5ml/vialSample diluent 6.0ml 3.0mlHRP-Conjugate reagent 10.0ml 5.0ml20X Wash solution 25ml 15mlChromogen Solution A 6.0ml 3.0mlChromogen Solution B 6.0ml 3.0mlStop Solution 6.0ml 3.0mlClosure plate membrane 2 2User manual 1 1Sealed bags 1 1Note: 1. Standard concentration was followed by: 200、100、50、25、12.5、6.25 ng/mL2. If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.PRECAUTIONS1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer. 2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents. 3. Do not use kit components beyond their expiration date. 4. Use only deionized or distilled water to dilute reagents. 5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided. 6. Use fresh disposable pipette tips for each transfer to avoid contamination. 7. Do not mix acid and sodium hypochlorite solutions. 8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed. 9. All samples should be disposed of in a manner that will inactivate viruses. 10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal. 11. Substrate Solution is easily contaminated. If bluish prior to use, do not use. 12. Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame. 13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).REAGENT PREPARATION AND STORAGEWash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C. ASSAY PROCEDURE1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.2. Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.3. Add 100μl of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.4. Wash the Microtiter Plate 4 times.Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame. Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.5. Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.6. Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.7. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.CALCULATION OF RESULTS1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis. 2. First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software. 3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration. 4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.6. Assay range: 6.25 ng/mL – 200 ng/mL.7. Sensitivity: The minimum detectable dose of Human C5a is typically less than 1.0 ng/mL.8. Cross-reactivity: This assay recognizes recombinant and natural Human C5a. No significant cross-reactivity or interference was observed.9. Storage: 2-8℃ (Use frequently); six months (-20℃)。10. Standard curve FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!
                点击进入上海卡努生物科技有限公司展台查看更多 我要投稿
                普教会△专题840*100

                版权与免责声明:

                ① 凡本网注明"来源:教育装备采购网"的◎所有作品,版权均属于教育装备采购网,未经本网授权不得转载、摘编或利用其它方式使用。已获本网授权⊙的作品,应@在授权范围内使用,并注明"来源:教育装备采购网"。违者本网将追究相关法律责任。

                ② 本网凡注明"来源:XXX(非本网)"的作品,均转载自其它媒体,转载目的在①于传递更多信息,并不代表本网赞同其观点和对其真实性负责,且不承担此类作品侵权行为的直接责任及连带责任。如其他媒◣体、网站或个人◣从本网下载使用,必须保留本网注明的"稿件来源",并自负版权等法律责任。

                ③ 如涉及≡作品内容、版权等问题,请在作品发表之日起两周内与本网联系,否则视为放弃相关权利←。

                2022云展会300*245