腾讯彩票

  • <tr id='wQm2Gt'><strong id='wQm2Gt'></strong><small id='wQm2Gt'></small><button id='wQm2Gt'></button><li id='wQm2Gt'><noscript id='wQm2Gt'><big id='wQm2Gt'></big><dt id='wQm2Gt'></dt></noscript></li></tr><ol id='wQm2Gt'><option id='wQm2Gt'><table id='wQm2Gt'><blockquote id='wQm2Gt'><tbody id='wQm2Gt'></tbody></blockquote></table></option></ol><u id='wQm2Gt'></u><kbd id='wQm2Gt'><kbd id='wQm2Gt'></kbd></kbd>

    <code id='wQm2Gt'><strong id='wQm2Gt'></strong></code>

    <fieldset id='wQm2Gt'></fieldset>
          <span id='wQm2Gt'></span>

              <ins id='wQm2Gt'></ins>
              <acronym id='wQm2Gt'><em id='wQm2Gt'></em><td id='wQm2Gt'><div id='wQm2Gt'></div></td></acronym><address id='wQm2Gt'><big id='wQm2Gt'><big id='wQm2Gt'></big><legend id='wQm2Gt'></legend></big></address>

              <i id='wQm2Gt'><div id='wQm2Gt'><ins id='wQm2Gt'></ins></div></i>
              <i id='wQm2Gt'></i>
            1. <dl id='wQm2Gt'></dl>
              1. <blockquote id='wQm2Gt'><q id='wQm2Gt'><noscript id='wQm2Gt'></noscript><dt id='wQm2Gt'></dt></q></blockquote><noframes id='wQm2Gt'><i id='wQm2Gt'></i>
                教育装备采购网
                长春智慧学校体育论坛1180*60
                教育装备展示〓厅
                www.freecchost.com
                教育装备采购网首页 > 产品库 > 产品分类大全 > 职教实训 > 家用电器(制冷制热)实训设备

                中央空调实验室设备,中央空调∮实验设备,中央空调实训设备,职业技能培训教学设备

                中央空调实验室设备,中央空调实验设备,中央空调实训设备,职业技能培训教学设备
                <
                • 中央空调实验室设备,中央空调实验设备,中央空调实训设备,职业技能培训教学设备
                >
                产品报价: 69000
                留言咨询
                加载中
                上海
                详细说明

                SBKT06型中央空调实验室设备

                随着社会的发展,人们的生活水平不断提高,中央空调在大型商场、宾馆、写字楼、商住楼等许多方面得到越来越广泛的应用。中央空高调的设计、管理、维修在现代生活中也越来越重要。为便于人们了解、学习中央空调的基本原理、基础知识,掌握其管理、维护及维修方法,本公司专业技术人员开发生产中央空调系列产品。

                为了更好地满足各大院校的教学需要,在原来开发的中央空调实验设备的基础上,配备了RS-232串行通讯接口,可直接与电脑连接,由电脑控制软件控制整个实验台的运行,包括:总控台启动、制冷、制热、冷却水泵、冷却风机、制冷水泵、压缩机、电磁阀、制热水泵做演示,制冷、制热的温度设定等。

                最大的特点是,通过传感器将空调状况实时反馈至电脑,能够同时显示蒸发器、冷凝器、模拟锅炉、冷却塔的进出口温度,房间风管温度,随时显示制冷或制热的设定温度。有利于教学记录※、采样、通过打印可提供进行理论分析的根据。本实验设备配备了电脑插口、电压表、电流表、压力表、温度显示器、工作指示灯、故障演示按钮。压缩机、蒸发器(透明盖)、冷凝器(透明盖)、压力控制▅器、毛细管、过滤器、膨胀阀、视液镜、储液器、喷淋式冷却塔、冷却一↘级泵、冷却二级泵、制冷一级泵、制冷二级泵等。

                中央空调实验设备是将中∏央空调微型化,同时保持整个中央空调系统的完整性和合理性。本实验台能单独演示中央空调的夏天制冷、冬天制热循环,控制系统由总控台采用数控电路控制。用温度显示器分别检测蒸发器、冷凝器、冷却塔、模拟锅炉的进出口温度,便于学员观察、了解各物理参数的变化情况和系统的工作状况。实验台增加了一些辅助结构,使其能人为地制造各种在实际中可能产生的系统故障,方便学员了ζ 解故障的产生和排除故障的方法。

                中央空调实验室设备,中央空调实验设备,中央空调实训设备,职业技能培训教学设备

                价格:69000元/套

                (一)总控台主要组成:电源总开关、电压表、电流表、压力表、温度控制器、温度显示器、工作指示灯、故障演」示开关等。

                (二)制冷系统主要组成:压缩机、蒸发器(透明盖)、冷凝器(透明盖)、压力控制器、毛细管、过滤器、膨胀阀、视液镜、储液器、喷淋式冷却塔、冷却一级泵〓、冷却二级泵,制冷一级泵、制冷二级泵等。

                (三)制热系统主要组成:电热式模拟锅炉、温度调节器、制热水泵乖。

                (四)制冷、制热系统循环示教板:分别用彩色灯光演示其循环过程。

                (五)中央空调制冷、制热循环输送管路用最新型彩色铝塑管以及铜件连【接,并标有明显的走向标志。输送管路经电磁阀、风机盘管输送给模拟房间、或模拟风管,根据所需调节风速开关或风量。

                  中央空调实验设备主要技术参数

                  

                主要技术参数

                 

                 

                 

                ~50Hz  220V

                额定功率

                2900W

                2300W

                额定电流

                14.0A

                11.0A

                R22  5Kg

                外形尺寸

                350×220×280(cm)

                冷却水泵

                2.5 m3/h   扬程>15

                制冷水泵

                1.8 m3/h   扬程>15

                制热水泵

                1.8 m3/h   扬程>15

                模拟锅炉

                1800W   8.5A

                风机盘管

                3500 m3/h

                冷热风管

                排热量1.6KV;排热面积8.5m2

                2100m3/h

                 

                注:以上参数若◇有变动,以产品所注参数为主。

                操作说明

                () 实验前准备工作

                接通总控台电流,合上空气开关,首先,查看微机控制台信息是否正常,观察有无绿灯闪亮,若没有要检查输入接口或电源。然后,将选择按▓钮选定“制冷”处,进行预加水。

                冷凝器侧预加水:将水灌入冷却塔卐的接水盘中,关闭截止阀F10,将冷却水泵按钮K1处于工作状态(绿灯亮),至冷凝器水加满为止,冷凝器水箱水满与否可能透过有机玻璃板观察到(注意:水不能满出①冷凝器外壳)。加好水后,关闭冷却水泵,并打开截○止阀F10

                蒸发器侧预加水:关闭截止阀F3F4,打开截止阀F2,将制冷水泵按钮K3处于工作状态(绿灯亮),由膨胀水箱水加至蒸发器中,加满为止,蒸发器水箱水满与否可以通过有机玻璃板观察到,加好之后,关闭制冷水泵,并关♂闭截止阀F2

                锅炉⊙测预加水:打开截止阀F3F4和排水阀F6,关闭F1F2,将制热水泵按钮K7处于工作状态(绿灯亮),往锅炉加水,直至排水阀F6有较大的水流出,然后关闭F6,关闭制热水泵,停止加水,再关闭截止阀F4

                ()操作过程

                1、制冷实验

                在确保水已加满后,打开截止阀K1K2,关闭截止阀F3F4。冷却水泵K1,冷却风机K2、制冷水泵K3、压缩机K4、电磁阀ⅠK5、电磁阀ⅡK6、处于工作状态(绿灯亮),制热水泵K7处于关闭状态(红灯亮)。选择功能按钮选定“制冷”处,把制冷温控传感器放入蒸发器内,所显示的是蒸发器的当时温度。根据要求选ω 择设定按钮,确定温度,(注:设定温度必须低于当时蒸发器的温度,否则,压缩机不能工作),此时,制冷指示灯亮。

                待制冷至设定的温度时,即会自动停机。第二次启动之前要将压缩机延时选择定为810分为宜,使压力平衡,方可启动。

                2、制热实验

                接通控制台电源,接通模拟锅炉加热按钮,将旋转钮选择打向40℃左右。打开截止阀F3F4,关闭截止阀F1F2,制热水泵处于工作状态(绿灯亮),将K1K2K3K4关闭状态,将功能选择按钮选定“制热”后,然后,根据要求选择设定按钮,确定温度,此时,制热指示红灯亮,当制热达到设定温度时,即会自动停机。

                3、温度︾巡测及风速调节由微机控制,可以同时显示所有当前温度和设定温度。

                手动控制,需分别按显示温度的按钮,通过温度显示器,观察当前温度。模拟房间,可根据需要进行开、关,风速Ⅰ、Ⅱ、Ⅲ档【进行演示。模拟风管,根据风口Ⅰ(散流器)、风口Ⅱ(可调散流器),进行演示。为了能使达到最佳演示效果,请分别进行模拟房间、模拟风道的演示

                中央空调故障、故¤障现象及恢复方法

                ()制冷故障

                序号

                故障名称

                故障产生办法

                故障现象

                故障解决方法

                备注

                1

                漏氟

                从截止阀JF4充氟口放氟

                风机盘◥管无冷风,系统压力偏低,膨胀阀后液管结霜

                加氟至正①常

                *

                2

                氟太多

                从截止阀JF4充氟口加氟至◤压缩机1.2倍电流

                风机盘管冷风不强,视液镜有液状制冷剂,系统压力偏高

                放氟至正常■电流

                 

                3

                膨胀阀损坏

                关截止阀JF4,全关即全◣堵,半关即半ㄨ堵

                视液镜有液状制冷剂,风机盘管无冷风

                完全打开截止阀Ⅱ

                 

                4

                压缩机吸

                气口堵塞

                关截止阀JF4,全关即全堵,半关即半堵

                风机盘管无冷风,视液镜有液状制冷剂,压缩机声音沉闷

                完全打开截止阀Ⅰ

                 

                5

                系统冷却侧

                水泵不转

                将按钮K1处于关闭状,红灯亮

                系统高压侧压力升高,电流增大,压缩机过载保护器断开

                将按钮恢复正常

                 

                6

                冷却塔风╳机

                不转

                将按钮K2处于关闭,红灯亮

                系统高压侧压力升高,电流增大

                将按钮恢复正常

                 

                7

                制冷水泵不

                将按钮K3处于关闭状态,红灯亮

                风机盘管无冷风,蒸发器侧水出现结冰现↑象

                将按钮恢复正常

                 

                8

                压缩机过载

                保护器损坏

                将按钮K4处于关闭状态,红灯亮

                压缩机不启动

                58分钟将按钮恢复正常

                 

                9

                压缩机启动

                电容故障

                 

                压缩机不启动,电流增大,过载保护断开

                 

                **

                10

                电磁阀

                将按钮K5处于关闭状态

                风机盘管无冷风吹出,蒸发器侧水出现结冰现象

                将按钮恢复正常

                 

                11

                室内侧漏水▓

                将塞子塞住水口或将出水管口抬高

                集水盘有积水

                拿掉塞子或恢复出水管口高度

                 

                注意:

                4、所有故障应单独模拟;

                5*:为了节约氟里昂及防止污染,此故障模拟方法可如下:

                在系统正常运行情况下,将截止阀JF1及截止阀JF3完全关闭,运行约半分钟后完全关闭截止阀JF2,打开截止阀JF1,即可模拟此故障。

                故障恢复方法:将截止阀JF2及截止阀JF3完全打开约半分钟后◎依次关闭截止阀JF2、截止阀JF3

                6**:模拟此故障极易引起压缩机损坏,本实验台不模拟此故障。

                (二)制热故障

                序号

                故障名称

                故障产生办法

                故障现象

                故障解决方法

                备注

                1

                制热水泵不转

                将按钮K7处于

                关闭状态

                风机盘管无

                热风吹出

                将按钮恢复正常

                 

                2

                电磁阀故障

                将按钮K5处于

                关闭状态

                风机盘管无

                热风吹出

                将按钮恢复正常

                *

                注意:

                1、所有故障应单独模拟;

                2*:故障同制冷;

                3K1K6故障演示操作(即按钮关闭状态)

                注意事项

                1、本实验台使用电源为单相220V~50Hz,允许电压波动范围为210242V,本实验台要求有独立的供电线路,电源引□线截面不小于4mm2。要求实验台有可靠接地!!!

                2、实验台中的制冷系统主机部分在搬运时绝对禁止倾斜。

                3、本实验台所有制冷剂为R22,禁止其它制冷剂代替。

                4、本实验▂台所有循环水应干净、无污染,每次作实验前应保证系统中有足够循环水,实验完成后,应将水排放干净。

                5、在给制↑冷系统加氟时,应控制压缩机运转电流在其额定运转电流的±10%偏差范围内。

                6、给实验台制造故障时,应尽快将他恢复正常,否则,长时间故障运行容易引起机器损坏。

                7、实验台后侧应留0.5米的距离。

                8、回气管温度若超过15度,应适当加入制冷剂。

                一、主要配置:

                1、制冷系统配置:

                1)、2P松下万宝空调压缩机器1

                2)、2P蒸发机器1

                3)、2P冷凝器1

                4)、蒸发器冷却水箱1

                5)、冷凝器冷却水箱1

                6)、高低压、压差控制器1

                7)、3/8制冷剂流动观察镜1

                8)、3/8手阀2

                9)、RF22NP5A热力膨胀阀1

                10)、3.5MPa抗震冷媒表高压压力表1

                11)、1.5MPa抗震冷媒表低压压力表1

                12)、1/4加液手阀1

                13)、水箱透明油机玻璃2

                14)、900×1100mm主机机组机架1

                15)、冷却塔31

                16)、25WZ15-0.55制冷水泵550W带热保护2

                17)、25WZ12-0.37冷却水泵2个带热保护370W

                18)、球阀4只控制制冷制热作用

                19)、电磁阀交流220V2只控制房间,风管是否送冷温气

                20)、热力膨胀阀1

                21)、900宽×900宽×1000mm模拟房间1

                22)、350风机盘管1

                23)、风机盘管控制开关1个三档

                24)、模拟风管1套,内裁面为35×34cm

                25)、4×6冷凝器风管盘管1

                26)、180W风管送◣风机1

                27)、45W冷却塔风机1

                28)、风管风机控制开关1

                二、制热系统:

                1HP501500W模拟锅炉1

                225WZ15-0.55制热水泵1

                3、模拟房间、风管、水箱同制冷系统

                三、中央空调系统演示木板1

                四、中央空调控制台1

                13.5Mpa抗震冷媒高压表1

                21.5MPa抗震冷媒低压表1

                330A电源总开关1

                4、交流220V电压表1

                5、直流30A电流表1

                6、数码温度显示器1

                7、温度选择轻确开关12

                8、制冷制热轻确开关4

                9、故障显示轻确开关7

                10、状态指示灯32

                11、铝塑板实验面板1

                12、实验台、实验桌1

                13、中央空调带微机接口1

                14、中央空调控制方法,即可通过实验台控制,又可通过电脑控制。

                15、中央空调电脑由需方配置,供方可代办。

                家电实验室设备、制冷制热实验台、变频空调实验台、中央空调实验室设备智能建筑实训设备

                SB-2002A7型变频空调制冷制热综合实验设备(第七代)

                SB-2002B6型制冷制热综合实验●室设备(第六代)

                SB-2002C5型制冷制热综合实验室设备(第五代)

                SB-KT2型仿真中央空调微机控制实验室设备带微机接口)

                SB-KT型仿真中央空调实验室设备

                中央空调微机控制实验台

                SB-99KGB型DVD十五合一智能视听家电多功能实验设备

                SB-99KGA1家用电器实验室设备(DVD十三合一、十二合一)家电实训设备(DVD十四合一)

                SB-99KGA1(DVD十一合一、十合一)家庭影院实验室

                SB-99KGB2(DVD十合一、九合一)家庭影院实验室

                SB-99EB型 家电验室设『备(DVD八合一)

                SB-99EC型家庭视听影院综合实验室设备(DVD七合一)

                家用电器多功能实验室设ξ备单元线路板配置

                DT-2000型透明仿真教学电梯模型

                双联六层透明仿真教学电梯模型

                DT-2008群控六层透明仿真教学电梯模型

                DT-2000六层透明仿真教学电梯模型

                DT-3000型教学实训组合电梯模型系列

                SBSW-DT09四层实物电梯实训考核设备

                中央空调微机控制实验台

                智能建筑实验实训装置

                智能建筑实验室实训设备报价 

                留言咨询
                姓名
                电话
                单位
                信箱
                留言内容
                提交留言
                联系我时,请说明是在教育装备采购网上看到的,谢谢!
                同类产品推荐