Electrophysiology Module 直接将Electrophysiology的数据读入SigmaPlot,立即展开绘图及分析的工作不需花费其它的接口数据撷取程序.可大量节省您的时间 ,包含Axon Instruments ABF files, Bruxton Corporation’ Acquire format and HEKA electronik’s Pulse format.
Directly Read Your Electrophysiology Data into SigmaPlot
The Electrophysiology Module is an add-on to SigmaPlot that allows you to directly import your acquired data into SigmaPlot without the need for an additional data acquisition program. The module saves you the time and effort of manually entering data into SigmaPlot so you can start your analysis and graphing right away. Use the easy point-and-click interface to import your data from commonly used file formats including Axon Instruments ABF files, Bruxton Corporations Acquire format and HEKA electroniks Pulse format. The file formats appear as a convenient drop down list in SigmaPlot
Electrophysiology Module - SigmaPlot Module
Directly Read Your Electrophysiology Data Into SigmaPlot
Electrophysiology Module is an add-on to SigmaPlot 2000 that allows you to directly import your acquired data into SigmaPlot, without the need for an additional data acquisition program. The module allows you to instantly read large data files into SigmaPlot, so you can start analyzing and graphing your data in no time. Use the easy point-and-click interface to import your data from commonly used file formats including Axon Instruments ABF files, Bruxton Corporations Acquire format and HEKA electroniks Pulse format. The file formats appear as a convenient drop down list in SigmaPlot.
Using the Section dialog, you can explicitly specify numerically the section to be imported.
Click to View Larger Image
Access Parts of Data Relevant To Your Analysis
The Electrophysiology Module provides a preview of your data. You can select only the part of the data of interest for your analysis. The module supports continuous and episodic data recording. Electrophysiology data files contain considerable information useful for analysis. The module provides access to this information, so you do not have to enter it separately into SigmaPlot. You can even use the information to automate analysis, determining the relationship between stimulus and response. Using the Section dialog, you can explicitly specify numerically the section to be imported.
The Acquire file format (Bruxton) supports continuous data recording and computer-controlled experiments.
Click to View Larger Image
Eliminate Errors By Getting the Right Data
Using this module, you do not have to retype scaling factor, time scales, or stimulus information thereby reducing the chances of making mistakes. Plus, in addition to the scaled acquired data and the stimulus pulse, the module provides information on the file structure, the file information like the date and time of recording, file comments, channel information, as well as file specific information. For example, in Axon Instruments ABF files, you can obtain each tag. For HEKA elektronik Pulse files, you can obtain information from the solution database. The Module also provides column labels that help identify the data. All this information dramatically reduces the chances for error and allows you work with greater speed and accuracy. You also save time by reducing errors when you are collaborating with your colleagues.
The Pulse file format (HEKA elektronik) supports episodic (computer-controlled stimulus) recording plus there are a variety of versions. Again, the module sorts this out on the fly.
Click to View Larger Image
Easily Automate Common Analysis and Graphing Tasks
Using the scripting interface to the module, you can write macros in your analysis program to read, analyze and graph your data. You even have access to the stimulus protocol when analyzing recordings based on computer stimulation. The script interface is extensive. You can use it to simply read data, or you can use it to automatically extract the information you need for data analysis. Once you read your data, you can start analyzing and graphing your data with award-winning SigmaPlot in no time. You can even exchange data with collaborators without having to use the same data acquisition system.
The ABF file format (Axon Instruments) supports both continuous data recording and episodic (computer-controlled stimulus) recording. For the different recording types all called ABF, the module figures out on the fly what type of data is involved and displays it correctly.
Click to View Larger Image
Analyze and Graph Your Data Easily
Once you import your data into SigmaPlot, analyzing your data and creating exact graphs is intuitive and easy with SigmaPlots MS- compatible award- winning interface, wizard technology and automation capabilities. You can get started and publish your results faster than you ever imagined. And, SigmaPlot provides the flexibility you need to create precise and compelling graphs. In fact, SigmaPlots graphing flexibility has inspired the readers of Scientific Computing and Instrumentation to award SigmaPlot their prestigious Readers Choice Award eight years running!
Notes
The Electrophysiology Module is intended for graphing and analysis of recorded data. Not all features of all files format are supported. For example, AxoScope voice tags cannot be retrieved using Electrophysiology Module. The amount of memory required depends on the data file format. Electrophysiology Module must be able to hold control information for the file being read in memory, as well as buffer data during reading. Generally 1MB to 4MB of free memory is required.